The TNC Male 1/2″ SuperFlex Clamp connector is designed for use with 1/2 inch SuperFlex coaxial cables. This connector features a clamp attachment method, providing a secure and reliable connection with minimal signal loss. It supports RF applications up to 11 GHz and is suitable for use in telecommunications, wireless communication systems, and other high-frequency environments. The TNC Male 1/2″ SuperFlex Clamp connector offers durability and flexibility for various installations.

1 user are viewing this product

### Tools and Materials Needed:
1. **TNC Male Connector (Clamp Style)**
2. **1/2″ Superflex (S.F.) Coaxial Cable**
3. **Cable Stripping Tool** (suitable for larger cables)
4. **Crimping Tool** (if required for any crimp components)
5. **Wrench or Pliers** (for clamping)
6. **Heat Shrink Tubing** (optional, for additional insulation and strain relief)

### Steps to Attach a TNC Male Connector to 1/2″ Superflex Cable:

1. **Prepare the Cable**:
– **Strip the Outer Jacket**: Use a cable stripping tool designed for larger cables to remove approximately 1.5 to 2 inches of the outer jacket from the 1/2″ Superflex cable. Be cautious not to damage the underlying braided shield.
– **Expose the Shielding**: Pull back the braided shield to reveal the dielectric insulation. Trim any excess shielding to ensure it fits neatly inside the connector.
– **Strip the Dielectric**: Strip the dielectric insulation to expose the center conductor. The length of exposed center conductor should be about 1/4 to 1/2 inch, depending on the connector’s specifications.

2. **Prepare the Connector**:
– **Slide on the Clamp or Ferrule**: If the TNC male connector has a clamp or ferrule, slide it onto the cable before inserting the cable into the connector. This clamp will secure the cable and the shield.
– **Insert the Cable**: Insert the prepared end of the 1/2″ Superflex cable into the TNC male connector. Ensure that the center conductor aligns with the center pin of the connector and that the shield fits properly against the clamp or ferrule area.

3. **Secure the Connection**:
– **Clamp the Connector**: Use a wrench or pliers to tighten the clamp or ferrule around the cable. This action will secure the connector to the cable, creating a solid mechanical connection. Make sure the clamp is tightened evenly to avoid gaps or uneven pressure.
– **Crimp the Center Pin**: If the connector includes a crimp-style center pin, use the crimping tool to crimp the center pin onto the center conductor of the cable. Ensure the center conductor is fully inserted into the pin before crimping.

4. **Assemble and Insulate** (Optional):
– **Apply Heat Shrink Tubing**: For added insulation and strain relief, slide heat shrink tubing over the joint and apply heat to shrink it tightly around the connector and cable.
– **Inspect the Assembly**: Check that the connector is securely attached, the clamp and center pin are properly crimped, and that there are no loose parts. Ensure that the center conductor and shield are properly connected.

5. **Test the Connection**:
– **Verify Connections**: Ensure that the connector is firmly attached and there are no loose parts.
– **Test Signal**: Use appropriate testing equipment to verify that the connection is working correctly and that there are no signal issues.

Brand

RF CONNECTOR HOUSE

Material

Brass

finish

Polished

Frequency Range

DC- 3 GHz

VSWR

≤ 1.15@(0~3GHz)

Dielectric strength

≥2500V RMS, at sea level

Dielectric Resistance

≥ 5000 M Ω

Characteristic Impedance

50Ω

Contact Resistance

Center Contact ≤ 1.0 m Ω, Outer Contact ≤ 0.25 m Ω

Temperature Range

– 40°C – +85 °C

Insertion Loss

≤ 0.08dB (@2200MHz)